58
7.12.3 Establishing equipotential bonding
DANGER
Risk of death from electric shock!
Disconnect the power plug before establishing
equipotential bonding.
Make sure the power plug cannot be accidentally
plugged back in.
The protective earth conductor conducts away any static charging
of the machine head.
Fig. 37: Establishing equipotential bonding
(1) - Connection at the controller
1. Tilt the machine head.
2. Feed the protective earth conductor from the connection (1)
on the rear side of the controller through the cutout in the table
top and plug it onto the tab connector (2) on the base plate.
Operating Instructions 867-M PREMIUM - 00.0 - 02/2015
1
(2) - Tab connector
Setup
2