6.13.3 Establishing equipotential bonding

The earthing cable conducts away any static charging to ground.
DANGER
Danger to life due to electric shock.
Disconnect the power plug before establishing
equipotential bonding.
Make sure the power plug cannot be unintentionally
reinserted.
Fig. 46: Establishing equipotential bonding
(1) - Connection point on the machine base plate
(2) - Earthing cable
(3) - Connection point on the controller
1. Secure earthing cable (2) to the connection point on
the controller (3).
2. Guide the earthing cable (2) upwards.
3. Secure earthing cable (2) with screw and tab connector
to the connection point on the machine base plate (1).