Feature & Operation
6-2-8 Indoor fan control in the Heating Mode
Indoor fan is controlled depending on the temperature of indoor heat exchanger in the heating mode.
G INDOOR FAN CONTROL
N When compressor begins operating
The temperature of indoor heat exchanger
N When compressor stops operating
The temperature of indoor heat exchanger
after 10 minutes when compressor stops operating
38
below 28°C
28°C ~ below 34°C
34°C ~ below 40°C
above 40°C
above 20°C
below 20°C
When compressor is on
40°C
34°C
28°C
20°C
Setting speed
L Speed
LL Speed
OFF
OFF
Compressor
Indoor fan speed
setting speed
Indoor fan speed
UL speed
When compressor is off
UL
ON
OFF
off
LL speed
L speed
off
off
Samsung Electronics