Automatic Operation; Samsung Electronics - Samsung AS09HPBN Training Manual

Hide thumbs Also See for AS09HPBN:
Table of Contents

Advertisement

Feature & Operation

6-2-3 Automatic Operation

When Automatic operation is set by the remote control, the air conditioner senses the difference between room temperature and
set temperature then automatically selects the operation mode and setting temperature.
1. In case of Heat pump model.
Ts+4
Ts+3
Ts+2
Ts+1
Ts
Ts-1
Ts-2
Ts-3
Ts-4
COMPor
Cooling / Heating
32
A area
B area
C area
C' area
B' area
A' area
ON
OFF
Cooling Mode
Mode
• A area : Tr ≥ Ts+3˚C
• B area : Ts+3˚C > Tr ≥ Ts+2˚C
• C area : Ts+2˚C > Tr ≥ Ts
Less
than
Over 1hour
1hour
Heating Mode
• C' area : Ts > Tr ≥ Ts-1˚C
• B' area : Ts-1˚C > Tr ≥ Ts-3˚C
• A' area : Ts-3˚C > Tr
Cooling Mode
N Tr : Room temperature.
N
Ts : Setting temperature.

Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

As12hpbnAs09hpaAs12hpa

Table of Contents