Samsung AS09HPBN Training Manual page 32

Hide thumbs Also See for AS09HPBN:
Table of Contents

Advertisement

6-2-1 Cooling Mode Operating
When selecting the Cooling Mode Operation, the unit will operate according to the set temperature by the remote control and the
operation is as shown below. Room temperature can be set in 1°C steps in the range of 16 to 30°C.
Compressor
6-2-2 Heating Mode Operation(In case of Heat pump model)
When selecting the Heating Mode Operation, the unit will operate according to the set temperature by the remote control and the
operation is as shown below. Room temperature can be set in 1°C steps in the range of 16 to 30°C.
Samsung Electronics
Room Temp.(°C)
Ts+1
Ts
ON
♦ Ts means Remote Controller setting Temperature
Room Temp.(°C)
Ts+5
Ts+3
ON
Compressor
Time
ON
OFF
ON
ON
OFF
Feature & Operation
Time