Controller Fault Codes

ERROR CODE
PROBLEM
SOLUTION
DELUXE
THE BATTERY NEEDS CHARGING OR THERE IS A BAD
LOW BATTERY VOLTAGE
CONNECTION TO THE BATTERY
TRACTION MOTOR
THE TRACTION MOTOR HAS A BAD CONNECTION, CHECK
DISCONNECTED
CONNECTIONS TO MOTOR
TRACTION MOTOR
SHORT
THE TRACTION MOTOR HAS A SHORT CIRCUIT TO THE
CIRCUIT
BATTERY
AUX FAULT or
CHECK AUX OUTPUT DEVICES, CHECK ALL ASSOCIATED
ACTUATOR (DECK or SQUE)
WIRING TO AUX DEVICES
OVERCURRENT
THE VACUUM MOTOR HAS EXCESSIVE CURRENT. CHECK
VACUUM MOTOR TRIP
FOR SHOR CIRCUITS OR OTHER DAMAGE.
THE BRUSH MOTOR HAS EXCESSIVE CURRENT, CHECK
BRUSH MOTOR TRIP
FOR SHORT CIRCUITS, PADS OR OTHER DAMAGE.
THE THROTTLE IS DEFLECTED OR ASSOCIATED WIRING
THROTTLE TRIP ERROR
HAS A BREAK OR SHORT CIRCUIT
THE CONTROL SYSTEM IS IN ERROR, CHECK ALL
CONTROL SYSTEM TRIP
CONNECTIONS TO CONTROLLER
THE SOLENOID HAS A BAD CONNECTION, CHECK
SOLENOID BRAKE
CONNECTION TO BRAKE
EXCESSIVE BATTERY VOLTAGE, CHECK FOR POOR
HIGH BATTERY VOLTAGE
BATTERY CONDITION