Onboard Charger (Optional)
Circuit Breaker must be off before unplugging
batteries.

Onboard Charger Programming

For machines equipped with optional on-board charger.
When replacing batteries, charger programming
changes may be required. If replacing batteries with
same type, (e.g. maintenance free batteries with main-
tenance free) no programming is required. When
batteries with different type (e.g.maintenance free with
wet cell), programming change are required. Failure to
make programming changes may lead to reduced
battery life.
1. Remove upper control panel.
2. Peel back label on charger to access dip switches.
3. Change switches to correct battery type.
DIP DIP DIP
1
2
OFF ON ON
LEAD ACID
ON OFF OFF
DISCOVER AGM
4. Replace charger label and install upper control
panel.
DIP
DIP DIP DIP DIP
3
4
5
6
7
8
ON
OFF ON ON OFF
OFF
OFF ON ON OFF