MT. VERNON E2 INSERT
Exhaust exits must be thoroughly cleaned.
Each exit is approximately 4 inches wide, 1
inch across, and 3 inches deep
Figure 18.1
NOTE It is normal to see a certain amount of wear of the
heat exchanger fi ns. You may notice some fl aking and pit-
ting on some of the pins. The heat exchanger system will
function as designed with as many as 15 of these pins miss-
ing.
18
5. Ash Removal System Inspection & Cleaning
Frequency: Monthly or after burning 50 bags of fuel.
By: Homeowner
a. Be sure the appliance is allowed to cool.
b. Open the front cast door and cycle the ash removal handle
- these should be inspected for functionality
c. Inspect for any degradation or deformation.

As the springs heat up and cool down they can lose
tension

If there is a gap showing above the fi repot bottom,
approximately 1/16 inch (1.59mm) or more, it means
the springs have lost their tension

Lost tension cannot keep the fl oor in the proper
position causing ignition problems and fuel falling
into the ash pan. If noted, call your dealer to replace
the springs.
RISK OF FIRE!
Do NOT store fuel:
• Closer than required clearances to combusti-
bles to appliance.
• Within space required for loading or ash re-
moval
Figure 18.2