INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
MT. VERNON E2 INSERT
PELLET APPLIANCE
Model(s):
MTVI-E2-MBK-C
MTVI-E2-PMH-C
CAUTION
Tested and approved for wood pellets only. Burning of
any other type of fuel voids your warranty.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafire.com
Pour obtenir une traduction française de ce manuel, s'il vous
00
plaît contacter votre revendeur ou visitez www.quadrafire.com
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
MTVI-E2-CSB-C
NOTE
If the information in these instruc-
tions is not followed exactly, a
fire could result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not over fire - If appliance or chimney
connector glows, you are over firing. Over
firing will void your warranty.
• Comply with all minimum clearances to
combustibles as specified. Failure to
comply may cause house fire.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fireplace.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other flammable
materials away.
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and na-
tional codes and regulations.
• Consult local building, fire officials or authorities having juris-
diction about restrictions, installation inspection, and permits.
7082-150C
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
CAUTION
January 4, 2018

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire MTVI-E2-MBK-C

  • Page 1 PELLET APPLIANCE damage, personal injury, or death. Model(s): • Do not store or use gasoline or other flam- MTVI-E2-MBK-C MTVI-E2-CSB-C mable vapors and liquids in the vicinity of this or any other appliance. MTVI-E2-PMH-C • Do not over fire - If appliance or chimney connector glows, you are over firing.
  • Page 2: Table Of Contents

    B. Avoiding Smoke and Odors ..........13 C. Negative Pressure ............14 D. Draft E. Chimney and Exhaust Connection ........14 F. Equivalent Feet of Pipe ............15 G. Pipe Selection Chart ............15 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7082-150C January 4, 2018...
  • Page 3: Important Safety Information

    - Tile 12, ULC S628-93, (UM) 84-HUD and ULC/ORD-C-1482. - Glass - Slate The Quadra-Fire Mt. Vernon E2 Pellet Insert Appliance meets Materials reported as passing ASTM E 136, Standard Test the U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to Method for Behavior of Metals, in a Vertical Tube Furnace of comply with 2020 particulate emission standards at 0.74 G/HR EPA...
  • Page 4: Getting Started

    MT VERNON E2 INSERT-C Install Guide Getting Started A. Design, Installation & Location Considerations Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: 1. Appliance Location • Windows NOTICE: Check building codes prior to installation. •...
  • Page 5: Tools And Supplies Needed

    MT VERNON E2 INSERT-C B. Tools And Supplies Needed C. Inspect Appliance and Components • Open the appliance and remove all the parts and articles Tools and building supplies normally required packed inside the Component Pack. Inspect all the parts for installation, unless installing into an existing and glass for shipping damage.
  • Page 6: Install Checklist

    MT VERNON E2 INSERT-C D. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. __________________________________________________________________________ Customer: ______________________________________________________________________ Date Installed: _______________________________________________________________________...
  • Page 7: Dimensions And Clearances

    MT VERNON E2 INSERT-C Dimensions and Clearances A. Appliance Dimensions 32 in [814mm] 32 in [814mm] 23-7/8 in [606mm] 23-7/8 in [606mm] 16-1/4 in 16-3/8 in [413mm] [415mm] 15 in 15-1/8 in 14-1/8 in 14-1/4 in [382mm] [384mm] [359mm] [361mm] 13 in 13-1/8 in [330mm]...
  • Page 8: Clearance To Combustibles, Us & Canada

    MT VERNON E2 INSERT-C B. Clearance To Combustibles, US & Canada Built-in Appliance - Rear Vent 26-7/8 in.** (683 mm) 36 in. (914 mm) 19-3/8 in.* *If interior of chase will be drywalled, add the (572 mm) thickness to this measurement. **From finished floor protection.
  • Page 9: Minimum Opening For Masonry & Zero Clearance Fireplaces

    MT VERNON E2 INSERT-C C. Minimum Opening for Masonry & Zero Clearance Fireplaces TOP TRIM 18-5/16 in 24-5/16 in (465mm) (618mm) 29-3/4 in (1010mm) Figure 9.3 HEARTH Minimum Opening Dimensions Inches Millimeters (406mm) EXTENSION Height 24-3/8 Front Width (Steel Panel Set) 32-1/4 Figure 9.1 Front Width (Cast Panel Set)
  • Page 10: Installation Into A Factory-Built Fireplace

    MT VERNON E2 INSERT-C F. Installation into a Factory-Built Fireplace The following is only one example as there are many differ- ent models of factory-built fireplaces. The following modifications are permissible: NOTE: This example is for reference only. Any modifica- •...
  • Page 11: Installation Into A Masonry Fireplace

    MT VERNON E2 INSERT-C G. Installation into a Masonry Fireplace WARNING All modifications that can be made to a Factory Built Fire- place can be made to a Masonry Fireplace. Risk of Fire! Follow venting manufacturer’s clearances and In addition DO NOT remove any brick or mortar from the instructions when installing venting system.
  • Page 12: Vent Information

    MT VERNON E2 INSERT-C Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Termination Cap Restricted Area Air Supply Inlet Gas Meter Figure 12.1 All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 13: Avoiding Smoke And Odors

    MT VERNON E2 INSERT-C B. Avoiding Smoke and Odors Vent Configurations Negative Pressure, Shut-Down and Electrical Power When installing a pellet appliance with a horizontal vent con- Failure figuration the frequency of power outages should be consid- To reduce the probability of back-drafting or burn-back in ered: the pellet appliance during power failure or shut down con- ditions, it must be able to draft naturally without exhaust...
  • Page 14: Negative Pressure

    2. Mobile Home: Approved for all Listed pellet vent. If using the 3 appliances and other combustion appliances to 6 inch (76-152mm) Top Vent Offset Adapter, use Listed double wall flue connector. A Quadra-Fire Outside Air Kit (OAK-3) must • Clothes dryers be used with manufactured home installations.
  • Page 15: Equivalent Feet Of Pipe

    MT VERNON E2 INSERT-C F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size. Vent surfaces get HOT, can cause burns if Figure 15.1.
  • Page 16: Venting Systems

    MT VERNON E2 INSERT-C Venting Systems A. Full Reline With Outside Air - Horizontal WARNING Fire Risk. CAUTION Inspection of Chimney: • Masonry chimney must be in good condition. Never draw outside combustion air from: • Meets minimum standard of NFPA 211 •...
  • Page 17: Full Reline With Outside Air - Vertical

    MT VERNON E2 INSERT-C B. Full Reline With Outside Air - Vertical NOTE: In Canada only a full reline is allowed per ULC NOTE: Check clearances carefully for this type of instal- S628, ORD ULC C1482-M1990. lation to ensure adequate room for outside air venting. 12 in [305mm] min.
  • Page 18: Appliance Set-Up

    MT VERNON E2 INSERT-C Appliance Set-Up A. Leveling System The leveling bolts are located on the sides of the appliance, front and rear. To access the bolts, remove the front access panels. Reach in and turn the bolt to the desired height to level the appliance.
  • Page 19: Removal Of Cast Sides

    MT VERNON E2 INSERT-C E. Surround and Trim Set - Cast Included in Surround Kit: (2) side panels, left and right; 3 inch high Set (1) panel top; (1) fastener package. Attach Trim to Insert from inside Insert. Included in Cast Trim Kit: (2) cast trim legs, left and right; (1) cast trim header;...
  • Page 20: Surround & Trim Set, Basic

    MT VERNON E2 INSERT-C F. Surround & Trim Set, Basic G. Optional Log Set Placement Instructions Included in Surround & Trim Kit: (2) corner brackets and set 2 PIECE LOG SET INSTALLATION screws; (1) trim set, 3 piece; (2) side panels; (1) top panel; 1.
  • Page 21: Programmable Wall Thermostat Installation

    Programmable Wall Thermostat Installation Programming Thermostat MT VERNON E2 INSERT-C The kit comes standard with a wall thermostat and 25’ of H. Programmable Wall Thermostat Installation The thermostat maintains a desired room temperature. wire. If you need to run more than 25’ make sure you use The 5-2 day programmable function allows one program Programming Thermostat a continuous strand of 18 to 22 gauge thermostat wire.
  • Page 22 MT VERNON E2 INSERT-C PROGRAMMABLE THERMOSTAT PART: WALL-STAT-P Programmable Wall Thermostat Installation Programming Thermostat The kit comes standard with a wall thermostat and 25’ of The thermostat maintains a desired room temperature. wire. If you need to run more than 25’ make sure you use The 5-2 day programmable function allows one program a continuous strand of 18 to 22 gauge thermostat wire.
  • Page 23: Power Cord

    MT VERNON E2 INSERT-C J. Trim Adjustment I. Power Cord 1. Prior to installing the power cord, turn the dial control “OFF”. 2. Make sure the wall receptacle has 120vac output. NOTE: Using a circuit protector can protect the appliance circuits from power surges.
  • Page 24: Mobile Home Installation

    MT VERNON E2 INSERT-C Mobile Home Installation You must use a Quadra-Fire Outside Air Kit CAUTION for installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE HOME An outside air inlet must be provided for the combustion air and FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED must remain clear of leaves, debris, ice and/or snow.
  • Page 25: Reference Materials

    MT VERNON E2 INSERT-C Reference Materials A. Service and Maintenance Log Date of Service Performed By Description of Service January 4, 2018 7082-150C...
  • Page 26 MT VERNON E2 INSERT-C Date of Service Performed By Description of Service 7082-150C January 4, 2018...
  • Page 27: Accessory List

    MT VERNON E2 INSERT-C B. Accessory List MTVI-E2-C Service Parts Beginning Manufacturing Date: July 2017 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 28 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL...

This manual is also suitable for:

Mtvi-e2-pmh-cMtvi-e2-csb-c

Table of Contents