Error Messages - Marantz SR7002 User Manual

User guide av surround receiver
Hide thumbs Also See for SR7002:
Table of Contents

Advertisement

ERROR MESSAGES

Displayed Error
MIC SET ERROR!!
A U T O
S E T U P
A U T O
S E T U P :
S T A R T
M A I N
R O O M
S U R R
B A C K :
M I C
S E T
E R R O R ! !
R E T U R N
NOISE ERROR!!
A U T O
S E T U P
S P E A K E R S
C H E C K :
N O I S E
E R R O R
R E T U R N
ANALYZE ERROR!!
A U T O
S E T U P
S P E A K E R S
C H E C K :
A N A L Y Z E
E R R O R
R E T U R N
N E X T
* Under ANALYZE ERROR, select "NEXT" with the 3/4 cursor
buttons and press the OK/ENTER button. A detail screen like the
following appears on the display.
S P E A K E R
C O N F I G
C H E C K
! !
S P E A K E R
F R O N T
L
:
Y E S
C E N T E R
:
N O N
F R O N T
R
:
Y E S
S U R R . R
:
N O N
S U R R . B
R
:
Y E S
S U R R . B
L
:
Y E S
S U R R . L
:
N O N
S U B
W
:
Y E S
R E T U R N
48
• The microphone is not properly connected.
2 C H
E X I T
• There is too much noise in the listening room to measure properly.
• Volume from the speakers is low.
! !
E X I T
• The speakers required for suitable playback were not detected.
• Speaker polarity is connected backwards.
! !
In the examples at left, the following trouble is detected.
• The polarity of the left and right channels of the front speakers is
backwards ([REV] appears on the display.)
• The surround speaker is not connected ([NON] is displayed), but
E X I T
the surround back speaker is connected
(In this kind of situation, [ERR] is displayed for all surround and
surround back speakers.)
R E V
An error is indicated in addition to the above if the speakers are
R E V
connected as follows.
E R R
• When using just one surround back speaker, but it is connected to
E R R
E R R
the surround back R-channel
E R R
(To use just one surround back speaker, connect it to the L-
channel.)
E X I T
Cause
• Connect the included microphone.
• Check the microphone connection.
• During measurement, turn off devices that make noise such as air
conditioners.
• Measure at a time when the surrounding area is quiet.
• Check the speaker that is indicated as having reversed polarity
([REV] can appear with some speakers even when properly
connected. In such case, ignore the error indication.)
• Check speaker direction and layout
How to Remedy

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr8002

Table of Contents