12. SYSTEM ERROR

The CPU inside the unit monitors peripheral interfaces and if a trouble is detected the following information is displayed on the
FLD.
1.
Trouble in DSP1
If communication with DSP1(Q610) is troubled more than 2 seconds, FLD shows below.
E
R
R
* This display stays and sound is muted.
2.
Trouble in DSP2
If communication with DSP2(Q640) is troubled more than 2 seconds, FLD shows below.
E
R
R
* This display stays and sound is muted.
3.
Trouble in ADC
If CAL signal from A/D converter(QK51, QK52) keeps high more than 2 seconds, FLD shows below.
E
R
R
* In analog input mode, this display stays and sound is muted.
4.
Trouble in EEPROM
If data from EEPROM(QU70) does not match, FLD shows below.
E
R
R
* After displaying it, Back-up Data is reset to default.
5.
Trouble in EEPROM I/F
If communication with EEPROM(QU70) is troubled more than 2 seconds, FLD shows below.
E
R
R
6.
Trouble in 5V Supply
If 5V supply to P604(DSP/CPU PCB) is troubled, FLD shows below.
E
R
R