Installation; Technical Specifications - Lincoln Electric INVERTEC V155-S 11327 Operator's Manual

Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATION V155-S
Input Voltages / 50 /60 Hz.
120Vac ± 10%
230Vac ± 10%
Duty Cycle
100%
30%
Output Current Range
5-155 Amps
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
INPUT VOLTAGE /
FREQUENCY (HZ)
230/60
120/60
Height
11.3
288 mm
OPERATING TEMPERATURE RANGE
-10°C to +40°C

INSTALLATION

INPUT - SINGLE PHASE ONLY
Max. Input Current at rated Output
100%
25A
23A
RATED OUTPUT
Output Amps
Output Volts
75A (Stick)
105A (TIG)
100A (Stick)
100A (TIG)
100A (Stick)
130A (TIG)
145A (Stick)
155A (TIG)
OUTPUT
Maximum Open Circuit Voltage
75 Volts Max.
TYPE S, SO ST, STO, OR EXTRA
HARD USAGE INPUT CORD AWG
3 Conductor, 12 AWG
PHYSICAL DIMENSIONS
Width
6.2 in.
158 mm
TEMPERATURE RANGES
V155-S
Input Power at Rated Output
30%
34 A
2.2kw
33 A
3.0kw
23.0 Vdc
14.2 Vdc
24.0 Vdc
14.0 Vdc
24.0 Vdc
15.2 Vdc
25.8 Vdc
16.2 Vdc
MAXIMUM TIME-DELAY CIRCUIT
BREAKER OR FUSE SIZE (AMPS)
Depth
15.4in.
392 mm
STORAGE TEMPERATURE RANGE
-25°C to +55°C
A-1
100%
30%
3.0kw
5.0kw
Input Circuit
120 Vac
230 Vac
120 Vac
230 Vac
Type of Output
DC
30
Weight
Approx. 14.7lbs.
6.7 kgs.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec v155-s 11326