INVERTEC
V160
OPERATOR'S MANUAL
MANUALE OPERATIVO
BEDIENUNGSANLEITUNG
MANUAL DE INSTRUCCIONES
MANUEL D'UTILISATION
BRUKSANVISNING OG DELELISTE
GEBRUIKSAANWIJZING
BRUKSANVISNING
INSTRUKCJA OBSŁUGI
LINCOLN ELECTRIC ITALIA S.r.l
Via Fratelli Canepa 8, 16010 Serrà Riccò (GE), Italia
www.lincolnelectriceurope.com

Advertisement

Table of Contents
loading

Summary of Contents for Lincoln Electric INVERTEC V160

  • Page 1 W83CE172 01/2004 Rev. 3 ® INVERTEC V160 OPERATOR’S MANUAL MANUALE OPERATIVO BEDIENUNGSANLEITUNG MANUAL DE INSTRUCCIONES MANUEL D'UTILISATION BRUKSANVISNING OG DELELISTE GEBRUIKSAANWIJZING BRUKSANVISNING INSTRUKCJA OBSŁUGI LINCOLN ELECTRIC ITALIA S.r.l Via Fratelli Canepa 8, 16010 Serrà Riccò (GE), Italia www.lincolnelectriceurope.com...
  • Page 2 överensstämmelse med följande standarder: i że zostało zaprojektowane zgodnie z wymaganiami następujących norm: EN 50199, EN 60974-1 Dario Gatti LINCOLN ELECTRIC ITALIA European Engineering Manager LINCOLN ELECTRIC ITALIA S.r.l., Via Fratelli Canepa 8, 16010 Serra Riccò (GE), Italia 06/02...
  • Page 3 Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 4: Installation And Operator Instructions

    CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used. Always keep cylinders in an upright position securely chained to a fixed support. Do not move or transport gas cylinders with the protection cap removed.
  • Page 5: Remote Control Connection

    approximately ¼ turn clockwise. Do not over tighten. welding modes: Stick (SMAW) and Lift TIG (GTAW). The V160-T machines have three welding modes: For V160-S machines, connect the gas hose from the Stick (SMAW), Lift TIG (GTAW) and HF TIG TIG torch to a gas regulator on the cylinder of gas to be (GTAW).
  • Page 6 When the mode switch is in the Lift TIG position, the stick welding functions are disabled and the For V160-T machines, the function of this control machine is ready for Lift TIG welding. Lift TIG is a knob is changed if a remote control is connected. If method of starting a TIG weld by first pressing the the Remote LED is ON, this indicates that a remote TIG torch electrode on the work piece in order to...
  • Page 7 is in Stick welding mode, the indicator will be OFF. As shown above, it is possible to press and hold the TIG torch trigger a second time during downslope to end the Q. Pulsing Frequency Control (V160-T Pulse only): downslope function and maintain the output current at When the pulsing function is ON, this control knob the Crater current.
  • Page 8: Electromagnetic Compatibility (Emc)

    Lincoln Electric. Before installing the machine, the operator must check the work area for any devices that may malfunction because of electromagnetic disturbances.
  • Page 9: Technical Specifications

    Technical Specifications V160: INPUT Input Voltage Input Power at Rated Output Frequency 230V ± 15% 5.4kW @ 100% Duty Cycle 50/60 Hertz (Hz) 7.0kW @ 35% Duty Cycle Single Phase RATED OUTPUT AT 40°C Duty Cycle Output Current Output Voltage (Based on a 10 min.