Section 4
D. Remove the white vinyl water distribution
tubing
•
Disconnect the hose from the water pump outlet.
•
Disconnect the hose from the dump valve (the tubing
pressure fits - pull tubing into evaporator
compartment).
E. Remove the water pump
•
Disconnect the water pump power cord.
POWER
CORD
WATER
PUMP
DO NOT SOAK
WATER PUMP
MOTOR IN
CLEANER OR
SANITIZER
SOLUTIONS
Water Pump Removal
•
Loosen the screws securing the pump mounting
bracket to the bulkhead.
•
Lift the pump and bracket assembly off the screws.
Part Number 000001114
F. Remove the water level probe
•
Loosen the screw that holds the water level probe in
place. The probe can easily be cleaned and sanitized
at this point without proceeding to step 2.
•
If complete removal is required, disconnect the wire
lead from the control board inside the electrical
control box.
LOOSEN
SCREWS
WATER
TROUGH
Step 7 Mix a solution of cleaner and warm water.
SV1618
Depending upon the amount of mineral buildup, a larger
quantity of solution may be required. Use the ratio in the
table below to mix enough solution to thoroughly clean
all parts.
Solution Type
Cleaner
Step 8 Use 1/2 of the cleaner/water mixture to clean all
components. The cleaner solution will foam when it
contacts lime scale and mineral deposits; once the
foaming stops use a soft-bristle nylon brush, sponge or
cloth (NOT a wire brush) to carefully clean the parts.
Soak parts for 5 minutes (15 - 20 minutes for heavily
scaled parts). Rinse all components with clean water.
SCREW
WATER
LEVEL
PROBE
Water Level Probe Removal
Water
1 gal. (4 l)
16 oz (500 ml) cleaner
Maintenance
WIRE
LEAD
ICE
MACHINE
SIDE
PANEL
SV1621
Mixed With
4-3