Harvest Sequence Water Purge - Manitowoc Q Use And Care Manual

Manitowoc ice machines installation and owner/operator use and care manual q model
Table of Contents

Advertisement

Section 3

HARVEST SEQUENCE WATER PURGE

The harvest sequence water purge adjustment may be
used when the ice machine is hooked up to special
water systems, such as a de-ionized water treatment
system.
The harvest sequence water purge is factory-set at
45 seconds. A shorter purge setting (with standard
water supplies such as city water) is not
recommended. This can increase water system
cleaning and sanitizing requirements.
The harvest sequence water purge may be set to 15,
30, or 45 seconds.
During the harvest sequence water purge, the water
fill valve energizes and de-energizes by time. The
water purge must be at the factory setting of 45
seconds for the water fill valve to energize during the
last 15 seconds of the water purge. If it is set to less
than 45 seconds, the water fill valve will not energize
during the water purge.
CONTROL
BOARD
WATER PURGE
ADJUSTMENT
Figure 3-10. Water Purge Adjustment
Part Number 000001114
Important
30
15
45
SV1617
Ice Machine Operation