Electrical Service And Repair - Heat & Glo Crescent II Owner's Manual

Hide thumbs Also See for Crescent II:
Table of Contents

Advertisement

SWITCH
BACK OF
SWITCH
12VDC
BLACK
PLUG
IN
J-BOX
CIRCUIT BOARD
Figure 12.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram - Standard Method
D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
J-BOX
BLACK WIRE CAN
BE PLUGGED INTO
ANY OF #1 - #5
LOCATIONS
ON THE HOT SIDE
GREEN
RED
YELLOW
1
C
3
2
1
C
3
2
T14
T14
T10
T10
T9
T9
EMBER LIGHTS
OFF/ON
HI/LOW
+ +
C2
C2
P1
P1
REM
REM
K3
K3
REM
REM
LINE NEU
K2
K2
J1
J1
T6
T6
T5
T5
HI HI
D1
D1
EMBER
D2
D2
12V
12V
R4
R4
COM
COM
C1
C1
C2
C2
SOLENOID
R1
R1
R1
R1
D3
D3
C1
C1
P2
P2
K1
K1
T16
T16
T15
T15
T2
T2
T1
T1
MADE IN
MADE IN
CANADA
CANADA
IPI
PRESS. SW
PRESS. SW
Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15
BLACK
WHITE
WHITE WIRE CAN BE
PLUGGED INTO ANY
OF #1 - #5 LOCATIONS
ON THE NEUTRAL SIDE
TRANSFORMER
3 VAC
PLUG IN
J-BOX
Note: Appliance will not operate unless properly grounded.
IGNITION
MODULE
3 VAC
WHT
ORG
GROUND
TO FIREPLACE
CHASSIS
VALVE
BROWN
BROWN
LIGHT SOCKETS
SOLENOID (NG ONLY)
INTERMITTENT
PILOT IGNITOR