ATEN KN4164Vl User Manual page 44

Kvm over ip switch
Table of Contents

Advertisement

KVM over IP Switch User Manual
Note: 1. For Power Over the Net™ units and Power Distribution Units, go
to Device Management/OOBC/Console Port Settings of the GUI
and select a Baud Rate of 38400 bps.
2. Make sure the CC Management function is disabled for both the
KN and PN.
3. The PON unit shown in the example is the PN0108. See
Supported Power Over the Net™ Units and Supported Power
Distribution Units, page 276, for a list of suitable units.
7. (Optional) Use Cat 5e cable to connect the KVM over IP switch's Modem
port to an SA0142 Adapter. Connect the Adapter's serial connector to the
modem's DB-9 port.
8. Ground the switch using proper grounding wire to connect the switch's
grounding terminal to a suitable grounded object.
Note: Do not omit this step. Proper grounding helps to prevent damage to
the unit from surges or static electricity.
9. Plug the power cords supplied with your package into the switch's power
socket, and then into an AC power source.
When using a single power socket, be sure to turn on the correct power
switch (see Power Switch, page 14). When using both power sockets,
either of the power switches can be used to turn on the KVM switch. To
enable dual power, turn on both power switches.
Note: If you are connecting the power to a UPS or an ALTUSEN PN9108/
PN0108, be sure to use the utility power cords supplied with your
package instead of standard power cords.
10. After the KVM over IP switch is cabled up you can turn on the power.
After it is powered up, you can turn on the servers.
26