Operating Mode - ATEN KN4164Vl User Manual

Kvm over ip switch
Table of Contents

Advertisement

Item
Temperature Warning
Message
Temperature

Operating Mode

The Operating Mode page is used to set working parameters, as described
below:
If Force all to grayscale is enabled, the remote displays of all devices
connected to the KVM over IP switch are changed to grayscale. This can
speed up I/O transfer in low bandwidth situations.
If Enable Client AP Device List is enabled, the switch appears in the
Server List when using the WinClient or Java Client AP (see Windows
Client AP Login, page 45, and Java Client AP Login, page 49). If this
option is not enabled, the switch can still be connected to, but its name will
not appear in the Server List.
Place a check in the checkbox to enable a temperature
warning message. If this function is enabled, when the
device's temperature drops below the Low threshold
setting, or exceeds the High threshold setting, the system
records the event in the system log. If it is not enabled, the
event will not be recorded.
The default for this function is enabled.
Temperature readings from the switch's built-in sensors are
indicated here and can be displayed in degrees Celsius or
Fahrenheit. See Clear Login Information, page 274
Chapter 8. Device Management
Description
155