Installing A Dimm - HP ProLiant DL580 User Manual

Gen9
Hide thumbs Also See for ProLiant DL580:
Table of Contents

Advertisement

Each populated channel must have a spare rank:
A single dual-rank DIMM is not a valid sparing configuration.
o
Two or more multi-rank DIMMs are recommended per channel.
o
All LRDIMMs (dual-, quad-, octal-rank) are treated as dual-rank DIMMs.
o
Mirrored Memory population guidelines
To configure memory for Mirrored Memory mode, observe these additional constraints:
For the server to support Mirrored Memory, all processors must have a valid mirroring configuration.
The minimum allowable configuration is two memory cartridges per processor.
Both memory cartridges for each processor must be populated with identical DIMM configurations.
Both memory risers inside the memory cartridge must be populated identically. Following general
DIMM slot population guidelines accomplishes this if DIMMs are installed in pairs in each cartridge.
Achieving optimum memory performance
The server includes 96 DIMM slots across four multi-core processors. While there are multiple DIMM
population configurations that may provide an ideal memory size, you can only achieve optimal
performance when populating DIMMs that can take advantage of the Intel Xeon Processor E7 series
architecture.
For optimum performance, HP recommends the following practices (listed in order of significance for memory
performance):
Use both memory controllers inside the processor and populate two memory cartridges for each
installed processor.
Populate each DDR4 channel in each memory cartridge. To achieve this, the minimum DIMM count per
cartridge is four DIMMs installed.
Populate DIMMs in cartridges identically across all processors.
RDIMMs have lower latency, LRDIMMs have higher capacity.

Installing a DIMM

To determine the ideal Memory RAS features for your setup, see "DIMM population guidelines for memory
modes (on page 53)."
WARNING:
processor memory drawer is very heavy when fully populated.
To install the component:
Power down the server (on page 25).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Remove the processor memory drawer shipping screws, if installed. Retain the screws for future use
3.
("Processor memory drawer shipping screw
Use caution when installing or removing the processor memory drawer. The
locations" on page 33).
Hardware options installation 55