Battery replacement

If the server no longer automatically displays the correct date and time, you may need to replace the battery
that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING:
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
To remove the component:
Power down the server (on page 25).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Extend the server from the rack (on page 27).
3.
Remove the access panel (on page 28).
4.
Remove the SPI board (on page 29).
5.
Remove the battery.
6.
IMPORTANT:
configuration. After replacing the battery, reconfigure the system through UEFI System Utilities.
The computer contains an internal lithium manganese dioxide, a vanadium
Replacing the system board battery resets the system ROM to its default
Battery replacement 107