Subsystem Related - Fujitsu PRIMEQUEST 2000 Series Message Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
1B6F0150
Incorrect connection (Illegal disconnect)
Meaning:
The PCI_Box cable connected to the indicated port may be removed when the related partition is power-on.
Corrective action:
Check the cable connected to the PCI_Box.
Severity:
Warning
1B6F01A0
Invalid ID SW operation
Meaning:
Incorrect operation of the ID switch.
Corrective action:
Restore the ID switch on the PCI_Box to its original setting.
Severity:
Warning
1BEF00FF
Cable is not connected
Meaning:
The IOU cable is not connected.
Corrective action:
No action is necessary.
Severity:
Info
C8A20100
Fatal Internal error
Meaning:
PCI card error was detected.
Corrective action
PCI card must be replaced. If the error is uncorrectable, the IOU, SB, DU or PCI-Box containing the PC card
must be replaced.
Severity:
Error

2.1.10 Subsystem related

Subsystem related messages are listed below.
1507071A
Boot Retry
Meaning:
As Heartbeat Lost was detected when the power was turned on, rescue retry was performed.
Corrective action:
No action is necessary.
Severity:
Info
280300A0
BMC Firmware Error
Meaning:
BMC firmware error has occurred.
Corrective action:
The system board must be replaced. If the error persists, the Active MMB must be replaced.
Severity:
Warning
24
CA92344-0540-06