Fujitsu PRIMEQUEST 2000 Series Message Reference page 138

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
28735
Adapter error (LEB map missing)
Meaning:
The LEB map was lost.
Corrective action:
Collect investigation materials (e.g., fjsnap, PrimeCollect), and contact your sales representative or a field
engineer.
Severity:
Warning
28737
Adapter error (Reserves depleted)
Meaning:
Reserved areas have been depleted.
Corrective action:
Check the format size. Release reserved space by formatting with a smaller size.
Severity:
Warning
28738
Adapter error (Attach failed)
Meaning:
Attach failed.
Corrective action:
Collect investigation materials (e.g., fjsnap, PrimeCollect), and contact your sales representative or a field
engineer.
Severity:
Warning
28739
Adapter error (Detach failed)
Meaning:
Detach failed.
Corrective action:
1. Remove the device by using the fio-detach command with the -f option (force removal).
2. If the error recurs, collect investigation materials (e.g., fjsnap, PrimeCollect), and contact your sales
representative or a field engineer.
Severity:
Warning
■PCIe-SSD (Windows) related
29010
Adapter error (Internal error)
800GB card
Meaning:
Internal error has occurred.
Corrective action:
Replace the PCIe-SSD card.
Severity:
Warning
29011
Adapter error (Write performance reduced)
800GB card
Meaning:
Write performance is degraded.
Corrective action:
It might be a temperature problem, power unit problem or life cycle problem etc...
Contact your sales representative or a field engineer.
Severity:
Warning