Temperature Sensor-Related Messages - Fujitsu PRIMEQUEST 2000 Series Message Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages

2.1.1 Temperature sensor-related messages

Temperature Sensor related messages are listed below.
010100FF
Lower Non-critical - going low Assert $$$
Meaning:
Low temperature warning has occurred.
Corrective action:
Check whether the monitored temperature has decreased as shown below, in the environment of the server
installed locations.
• Window left open in cold weather
• Air conditioner temperature setting, etc.
For PSU_S and PSU_P:
If the Inlet Temp is normal and PSU_S or PSU_P Temp is abnormal, please replace PSU_S or PSU_P.
Severity:
Warning
010107FF
Upper Non-critical - going high Assert $$$
Meaning:
High temperature warning has occurred.
Corrective action:
For Inlet Temp: Check the installation environment.
For PCIeSW Temp:
If the Inlet Temp is normal but the PCIe SW Temp is abnormal, check the inside and outside of the cabinet
for clogged filter or waste paper being stuck, that is interfering with the cooling.
Severity:
Warning
010109FF
Upper Critical - going high Assert $$$
Meaning:
High temperature error has occurred.
Corrective action:
For Inlet Temp: Check the installation environment.
For PCIe SW Temp:
If the Inlet Temp is normal, but the PCIe SW Temp is abnormal, check the inside and outside of the cabinet
for clogged filter or waste paper being stuck, that is interfering with the cooling.
When the situation does not improve it, replace the unit.
Severity:
Error
01010BFF
Upper Non-recoverable - going high Assert $$$ ℃ threshold: $$$ ℃
Meaning:
High temperature error has occurred.
Corrective action:
For Inlet Temp: Check the installation environment.
For PCIe SW Temp:
If the Inlet Temp is normal, but the PCIe SW Temp is abnormal, check the inside and outside of the cabinet
for clogged filter or waste paper being stuck, that is interfering with the cooling.
When the situation does not improve it, replace the unit.
Severity:
Error
018100FF
Lower Non-critical - going low Deassert $$$℃ threshold: $$$℃
Meaning:
Low-temperature warning was canceled.
Corrective action:
No action is necessary.
Severity:
Info
C threshold: $$$