MMB Messages
13146
Adapter error (operation failed)
Meaning:
The SAS persistent operation failed.
Corrective action:
Collect the data for investigation (dump or fjsnap). Contact your sales representative or a field engineer.
Replace the adapter.
Severity:
Warning
13147
Adapter error (Controller disabled)
Meaning:
The controller is not in the active state.
Corrective action:
The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer.
Severity:
Warning
13153
Adapter error (readl: detects master abort)
Meaning:
A master abort occurred in PCI read. The operation ran out of retries.
Corrective action:
The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer.
Severity:
Warning
13161
Adapter error (IOC Not operational)
Meaning:
The adapter is not in the operational state.
Corrective action:
The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer.
Severity:
Warning
13163
Adapter error (ioc_state: DOORBELL_ACTIVE)
Meaning:
The adapter has the DOORBELL_ACTIVE flag turned on.
Corrective action:
The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer.
Severity:
Warning
13173
Adapter error (no suitable DMA mask)
Meaning:
An invalid DMA mask was detected during adapter installation.
Corrective action:
An HBA or a driver has a fault. If the error keeps recurring, contact your sales representative or a field
engineer.
Severity:
Warning
13176
Adapter error (HardReset FAILED!!)
Meaning:
The hard reset of the adapter failed.
Corrective action:
The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer.
Severity:
Warning
CA92344-0540-06