Fujitsu PRIMEQUEST 2000 Series Message Reference page 79

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
E76F05FF
Physical disk rebuilding model=$$
Meaning:
The HDD rebuilding is in progress.
Corrective action:
No action is necessary.
Severity:
Info
E76F06FF
Physical disk Global Hot Spare created model=$$
Meaning:
The HDD global hot spare was created.
Corrective action:
No action is necessary.
Severity:
Info
E76F07FF
Physical disk bad block table is full model=%m
Meaning:
The bad block table of HDD is full.
Corrective action:
Replace the HDD.
Severity:
Warning
E76F08FF
Physical disk shielded model=%m
Meaning:
The HDD is shielded state.
Corrective action:
Replace the HDD.
Severity:
Warning
E7EF06FF
Physical disk Global Hot Spare deleted model=$$
Meaning:
The HDD global hot spare was deleted.
Corrective action:
No action is necessary.
Severity:
Info
E77E01FF
Logical drive partially degraded
Meaning:
The redundancy is kept though the logical drive did degradation.
Corrective action:
Replace the HDD.
Severity:
Warning
E77E02FF
Logical drive degraded
Meaning:
The logical drive did degradation and the redundancy was lost.
Corrective action:
Replace the HDD.
Severity:
Warning