Sony F65 Operation Manual page 50

Digital motion picture camera
Hide thumbs Also See for F65:
Table of Contents

Advertisement

Page
Configuration
item
<Fan Mode>
Fan Mode
Fan operating
mode select
<Date/Hour
Date
Meter>
Time
Date/Time
settings and
Hour Meter
accumulated ON
time display
Date Type
<Sync>
Genlock
Sync signal
Input Signal
settings
Status
<Battery Alarm>
DC IN (24V) Type
Supply voltage
Near End
settings
End
DC IN (12V) Type
Near End
End
50
VF Menu List
Default
Settings
Auto2
Auto1, Auto2, Min, Max
--
yyyy/mm/dd
--
hh:mm
--
0H to 99999H
Y/Mn/D
Y/Mn/D, Mn/D
HD-Y
HD-Y, HD-SDI
--
Locked, Not Locked,
No Signal
Type1
Type1, Type2
22.2 V
20.5 V to 30.0 V
21.6 V
20.0 V to 24.0 V
Type1
Type1, Type2
11.1 V
11.0 V to 17.0 V
10.8 V
10.5 V to 14.0 V
Remarks
Auto1: Automatic control, according to
the internal temperature.
Auto2: Automatic control, according to
the internal temperature, and
maintains quiet operation when
recording.
Min: Quiet mode, without
synchronization with recording (can
be used at ambient temperatures of
less than 30°C (86°F)).
Max: High-speed mode, fan rotates at
maximum speed.
Sets the current date.
Sets the current time.
Displays the accumulated powered-ON
time since reset from the Service menu.
Selects the date display format.
Selects the input connector for the
external sync signal. The genlock signal
must be reapplied after modifying this
setting.
HD-Y: HD 3-level sync
HD-SDI: HD-SDI input
Display only. Locked: Synchronized
successfully.
Not Locked: Not synchronized.
No Signal: There is no input signal.
Selects the 24 V system supply settings.
Sets the power supply voltage drop
warning level for the 24 V supply.
Sets the power supply exhausted
warning level for the 24 V supply.
Selects the 12 V system supply settings.
Sets the power supply voltage drop
warning level for the 12 V supply.
Sets the power supply exhausted
warning level for the 12 V supply.

Advertisement

Table of Contents
loading

Table of Contents