Fujitsu SE700 Operating Manual page 77

Server bs2000
Hide thumbs Also See for SE700:
Table of Contents

Advertisement

Switching the server on and off
Alternatively you can switch the Server Unit off by pressing the STAND-BY button on the
server's control panel (see
BY in AUXILIARY FRAME: POWER STAND-BY/IMPL). The BS2000 system should
already have been shut down.
i
3. Switch off the optional Server Units
As the administrator or a privileged operator, switch off the Server Unit using the
Ê
SE Manager (menu Hardware → Server (SE<model>, Units tab, "Switch off" function),
see the "Operation and Administration" manual [5].
When the Server Unit is switched off, the BS2000 system is shut down properly taking
into account the remaining runtime specified.
Before the Server Unit is switched off, the power-on indicator lights up green, and after
it has been switched off, it lights up orange. Check this before continuing.
i
4. Switch off the MU
Switch off the MU using the SE Manager (menu Hardware → Server (SE<model>, Units
Ê
tab, "Switch off" function), see the "Operation and Administration" manual [5]
Before the MU is switched off, the power-on indicator lights up green, and after it has
been switched off, it lights up orange (item 11 in
before continuing.
5. Switch off the optional hardware components
Switch off the ETERNUS LT40 S2 tape library using the On/Off switch on the front (see
Ê
the "Additive Components" Operating Manual [4]).
Switch off any other connected hardware components.
Ê
U41858-J-Z126-1-76
page
The control panel and SVP frames of the Server Unit are described in the "Server
Unit /390" Operating Manual [2].
The controls and indicators of the Server Unit are described in the "Server Unit
x86" Operating Manual [3].
Switching the SE700 / SE500 on and off
42) or via the SVP console (menu item POWER STAND-
figure 10 on page
49). Check this
77

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se500Se300

Table of Contents