Installing the Solar-Set

Immersion heater

If an EHE immersion heater is
installed (accessory), we would
recommend to do this prior to fitting
the base support for the Solar-Sets,
but to leave the electrical connection
until later.
Installation instructions,
immersion heater EHE
!
Please note
To prevent equipment damage,
cables must not come into con-
tact with hot parts.
Ensure sufficient thermal insu-
lation between the cables and
hot pipework.
6
&
Route the supply cable of the EHE
immersion heater on the right side
of the base support and secure with
the cable ties supplied.
&
Remove the cover from the facia of
the Solar-Set, enabling the facia to
be pulled over the fitted EHE immer-
sion heater.
If no EHE immersion heater is
installed: Seal in the plug (R 1½")
supplied into the free female connec-
tion above the sensor well (P see
page 4). The cover remains fitted to
the solar-Set facia.