B Switch On The Appliance; B Press The Reset Button For 3 Seconds And Release It; After Releasing The Appliance Re-Starts; Go To 7 - Worcester CDi Combi N.G Service Booklet

Floor mounted and wall hung rsf gas fired condensing boilers
Table of Contents

Advertisement

EA
and RESET button and fault indicator LED are flashing.
During operation: flame not detected.
Check
B Switch OFF the appliance.
5.
B Disconnect the boiler power
connection.
Is the earth connection correct?
6.
Is the condensate trap blocked?
7.
Is diaphragm in air/gas manifold fitted
correctly (see installation
instructions)?
B Open air/gas manifold.
B Check diaphragm for correct
orientation, soiling and splitting.
Is diaphragm OK?
8.
Check the gas valve.
B Switch OFF the appliance.
B Un-plug the connectors from the
gas valve.
B Measure the gas valve coils I and
II electrical resistance.
R = 164± 40 Ω?
B Remove gas valve and check inlet filter
for blockage.
Tab. 25 EA Error codes
8 716 115 748 (2009/09)
Supplied By www.heating spares.co Tel. 0161 620 6677
Action
B Reconnect the appliance power connection.
yes:

B Switch ON the appliance.

EA? go to 6
B Correct the electrical connection.
no:
B Reconnect the appliance power connection.
B Switch ON the appliance.

B Press the reset button for 3 seconds and release it.

After releasing the appliance re-starts.

EA? go to 6
yes:
B Clean out condensation trap discharge pipe.
B Press the reset button for 3 seconds and release it.
After releasing the appliance re-starts.
EA? go to 7

go to 7

no:
B Close air/gas manifold (see installation
yes:
instructions).
go to 8
B Insert diaphragm in the fan intake tube as per
no:
installation instructions so that the flaps open
upwards.
B Close air/gas manifold (see installation
instructions).
EA? go to 8
B Reconnect the connectors.
yes:
B Switch ON the appliance.
B Press the reset button for 3 seconds and release it.
After releasing the appliance re-starts.
EA? go to 9
B Turn off gas valve.
no:
B Disconnect the boiler power connection.
B Change the gas valve.
B Open the gas valve.
B Reconnect the connectors.
B Reconnect the appliance power connection.
B Switch ON the appliance.
B Check appliance for leaks.
B Press the reset button for 3 seconds and release it.
After releasing the appliance re-starts.
EA? go to 9
RECTIFYING FAULTS