Boiler Service Functions Cdi, Highflow Cdi & Fs Cdi Regular; First Service Level - Worcester CDi Combi N.G Service Booklet

Floor mounted and wall hung rsf gas fired condensing boilers
Table of Contents

Advertisement

6
BOILER SERVICE FUNCTIONS CDi, HIGHFLOW CDi
& FS CDi REGULAR
6.1
FIRST SERVICE LEVEL (PRESSING THE
Description
1.A
Max. output (heating)
2.b
Max. flow temperature
2.C
Air purge mode
(burner keeps off while air purge mode
is on)
2.F
Operating mode
3.b
Anti-cycle time
3.C
Anti-cycle flow temperature differential
3.F
Burner off after DHW demand (hot
water) (combi only)
4.F
Syphon-fill programme
5.b
Fan over-run time
6.A
Last fault
6.d
Actual flow rate turbine (combi only)
6.E
Programmer input
Tab. 8
Highflow CDi & FS CDi Regular service - first level
8 716 115 748 (2009/09)
Supplied By www.heating spares.co Tel. 0161 620 6677
BOILER SERVICE FUNCTIONS CDI, HIGHFLOW CDI & FS CDI REGULAR
BUTTON FOR APPROX. 10 SECONDS)
Range adjustable from - to/
Display
Description
*-U0
min adjustable output - 100%
35-88
35 - 88 °C
00-02
0 off
1 on, automatic deactivation (on
for 8 minutes, then off)
2 permanent on
00-02
0 Normal
1 Minimal (for 15 min)
2 Maximal (for 15 min)
00-15
0 - 15 min
00-30
0-30 K
(Note: 1K = ^ 1 °C)
00-30
0 - 30 min
(0 = 10sec)
00-01
0 off,
1 on, boiler min. output
01-18
1-18 (= 10 sec - 180 sec)
00 - FF
last fault code can be displayed
00-99
0-99 l/min
00-11
00, 01, 10, 11
(left digit: heating,
right digit: hotwater)
Reset Value
(after parameter
reset)
depends on
appliance type
88 °C
01
00
03 min
10 K
01 min
01
03 (30 sec)
00
read only
read only
23