B Top Up System; B Vent Appliance; B Press The Reset Button For 3 Seconds And Release It; After Releasing The Appliance Re-Starts - Worcester CDi Combi N.G Service Booklet

Floor mounted and wall hung rsf gas fired condensing boilers
Table of Contents

Advertisement

E9
and button reset and fault indicator LED are flashing.
Safety temperature circuit has tripped.
Check
1.
Type of CH system:
Is the appliance installed in a fully
pumped sealed system?
2.
Open vented CH system:
Is there enough water in the feed
and expansion tank?
Fully pumped sealed system:
3.
Is the heating pressure between 1
and 2 bar (sealed systems)?
Is the pump seized?
4.
Lead disconnected from flue safety
5.
temperature limiter and/or CH flow
safety temperature limiter?
Tab. 24 E9 Error codes
8 716 115 748 (2009/09)
Supplied By www.heating spares.co Tel. 0161 620 6677
Action
go to 3
yes:
go to 2
no:
go to 4
yes:
no:
E9? go to 4
go to 4
yes:
no:

B Top up system.

B Vent appliance.

B Press the reset button for 3 seconds and release it.

After releasing the appliance re-starts.

B Free/release the pump.
yes:
If pump won't start:
B Drain appliance.
B Change the pump (see Installation Instructions).
B Fill system, vent and re-pressurise (see installation
instructions).
E9? go to 5
go to 5
no:
B Switch OFF the appliance.
yes:
B Reconnect lead.
E9? go to 4
no:
RECTIFYING FAULTS