Viessmann VITOCAL 222-S Installation And Service Instructions Manual page 31

Type awt-ac 221.a04 to a13 compact heat pumps, split version for heating and cooling operation
Table of Contents

Advertisement

Installing the internal unit
Assembly and sealing faces to note
1. With the pipe outlets, ensure dia-
phragm grommets A are seated
correctly.
Seal diaphragm grommets A with
adhesive tape if necessary.
(cont.)
2. Fit the cylinder module in reverse
order to that described on page 25.
!
Please note
Make tight hydraulic connec-
tions between the heat pump
module and cylinder module.
With pipe outlets, ensure lock-
ing tabs C are seated cor-
rectly (see following illustra-
tion).
!
Please note
Seal the appliance so it is
soundproof and impermea-
ble.
The sealing tape on the side
panels must be in close con-
tact with sealing faces B on
the casing (see following illus-
tration).
Installation sequence
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents