Viessmann VITOCAL 222-S Installation And Service Instructions Manual page 105

Type awt-ac 221.a04 to a13 compact heat pumps, split version for heating and cooling operation
Table of Contents

Advertisement

Repairs
(cont.)
Temperature sensors in external unit (no marking)
Type NTC 10 kΩ
1000
100
10
1
0.1
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
Temperature in °C
Type NTC 50 kΩ
1000
100
10
1
0.1
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
Temperature in °C
Checking fuses
For fuse locations, see from page 49.
■ Fuse F1 is located on the mains ter-
minal of the heat pump control unit.
■ Fuse F3 is located on the main PCB.
■ Fuse F101 is located on the AVI PCB.
Fuses F1 and F3:
■ 6.3 AH (slow), 250 V~
■ Max. power loss ≤ 2.5 W
Fuse F101:
■ 1.0 AL (slow)
■ Max. power loss ≤ 2.5 W
Troubleshooting
105

Hide quick links:

Advertisement

Table of Contents
loading