Specification
(cont.)
Type AWT-AC
Electrical values
Internal unit
Heat pump control
unit/PCB
■ Rated voltage, con-
trol unit/PCB
■ Fuse protection,
power supply
■ Internal fuse
Instantaneous heat-
ing water heater
■ Rated voltage
■ Heating output
■ Fuse protection,
power supply
Electrical power con-
sumption
■ Fan (max.)
■ External unit (max.)
■ Secondary pump
(PWM)
■ Control unit/PCB, ex-
ternal unit (max.)
■ Control unit/PCB, in-
ternal unit (max.)
■ Max. rating, control
unit/PCB
Cooling circuit
Refrigerant
Refrigerant charge
Top-up amount for line
lengths >12 m to
≤30 m
Compressor (hermeti-
cally sealed)
Permiss. operating
pressure
■ High pressure side
■ Low pressure side
221.A04
kW
8.8
3xB16A
W
65
kW
3.0
W
W
150
W
5
W
1000
R410A
kg
1.2
g/m
20
Type
Rotating
piston
bar
43
MPa
4.3
bar
43
MPa
4.3
221.A07
221.A10
1/N/PE 230 V/50 Hz
1xB16A
6.3A (slow)/250 V
1/N/PE 230 V/50 Hz
3/N/PE 400 V/50 Hz
8.8
8.8
3xB16A
3xB16A
70
130
3.6
5.8
3 – 50
150
150
5
1000
1000
R410A
R410A
2.15
2.95
60
60
Rotating
Scroll
piston
43
43
4.3
4.3
43
43
4.3
4.3
Specification
221.A13
8.8
3xB16A
130
5.8
3 – 70
150
5
5
1000
R410A
2.95
60
Scroll
43
4.3
43
4.3
137