1

Important Safety Information

A. Appliance Certifi cation
Model
Mt. Vernon Pellet Stove E2
Laboratory
OMNI Test Laboratories, Inc.
Report No.
061-S-83-2
Type
Solid Fuel Room Heater, Pellet and
Shelled Corn Fuel Burning Type
Standard
ASTM E1509-12, ULC S627-00 and
(UM) 84-HUD, Mobile Home Approved.
FCC
Complies with Part 15 of FCC Rules.
Operation is subject to the following
two conditions: (1) this device may not
cause harmful interference, and (2) this
device must accept any interference
received, including interference that may
cause undesired operation.
NOTICE: This installation must conform with local codes. In
the absence of local codes you must comply with the ASTM
E1509-12, ULC S627-00, (UM) 84-HUD and ULC/ORD-
C-1482.
The Quadra-Fire Mt. Vernon E2 Pellet Heater meets the U.S.
Environmental Protection Agency's emission limits for pellet
heaters sold after May 15, 2015.
This pellet heater needs periodic inspection and repair for
proper operation. It is against federal regulations to operate
this pellet heater in a manner inconsistent with operating
instructions in this manual.
B. BTU & Effi ciency Specifi cations
EPA Certifi cation #: 984-15
EPA Certifi ed Emissions: 0.5 grams per hour
*LHV Tested Effi ciency: 81.6 %
**HHV Tested Effi ciency: 75.5 %
***EPA BTU Output: 13,900 to 42,200 / hr.
****BTU Input: 18,100 to 55,000 / hr.
Vent Size: 3 or 4 inches, "L" or "PL"
Hopper Capacity: 80 lbs.
* Weighted average LHV effi ciency using data collected during
EPA emissions test.
**Weighted average HHV effi ciency using data collected during
EPA emissions test.
***A range of BTU outputs based on EPA Default Effi ciency and
the burn rates from the low and high EPA tests.
****Based on the maximum feed rate per hour multiplied by
approximately 8600 BTU's which is the average BTU's from a
pound of pellets.
C. Glass Specifi cations
This stove is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
July 1, 2015
Fuel Wood Pellets
D. Electrical Rating
115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps
E. Mobile Home Approved
• This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
• The structural integrity of the mobile home fl oor, ceil-
ing, and walls must be maintained.
• The appliance must be properly grounded to the
frame of the mobile home and use only Listed pellet
vent Class "L" or "PL" connector pipe.
• Outside Air Kit, part OAK-3 must be installed in a mo-
bile home installation.
F. Non-Combustible Materials
Material which will not ignite and burn, composed of any
combination of the following:
- Steel
- Plaster
- Concrete
- Tile
Materials reported as passing ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace of 750° C.
G. Combustible Materials
Material made of/or surfaced with any of the following
materials:
- Wood
- Plant Fibers
- Plywood/OSB
Any material that can ignite and burn: fl ame proofed or not,
plastered or un-plastered.
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided by,
the following actions:
• Installation and use of any damaged appliance.
• Modifi cation of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved by
Hearth & Home Technologies.
• Operating appliance without fully assembling all components.
• Operating appliance without legs attached (if supplied with unit).
• Do NOT Overfi re - If appliance or chimney connector glows,
you are overfi ring.
Any such action that may cause a fi re hazard.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage.
For assistance or additional information, consult a qualifi ed installer,
service agency or your dealer.
NOTE: Hearth & Home Technologies, manufacturer of this appli-
ance, reserves the right to alter its products, their specifi cations
and/or price without notice.
7080-131H
MT VERNON E2
- Brick
- Iron
- Glass
- Slate
- Compressed Paper
- Plastic
- Sheet Rock (drywall)
WARNING