Product Specifications; Limited Warranty - Braun NTF 3000 Owner's Manual

No touch + forehead
Hide thumbs Also See for NTF 3000:
Table of Contents

Advertisement

Limited warranty

This product comes with limited warranty commencing on the date of
purchase (See warranty card for details). Within the warranty period we will
eliminate, free of charge, any defects in the appliance resulting from faults in
materials or workmanship, by replacing the complete appliance.
This warranty is applicable only for the appliance supplied by the appointed
distributor. This warranty does not cover: damage due to improper use,
normal wear or use as well as defects that have a negligible effect on the
value or operation of the appliance. The warranty becomes void if repairs are
undertaken by unauthorized persons and if original Braun parts are not used.

Product specifications

Type:
No touch + forehead thermometer (NTF 3000)
Measuring range:
34.4°C ( 93.9°F ) – 42.2°C (108°F )
Resolution:
0.1°C (0.1°F )
Laboratory Accuracy
± 0.2°C (± 0.4°F) for the range 35-42°C (95-107.6°F)
± 0.3°C (± 0.5°F) for outside that range
(Ambient Temperature: 15 to 40°C ( 59 to 104°F )
Display:
Liquid Crystal Display, 4 digits plus special icons
Acoustic:
Normal temp range=single long beep for 2 sec duration
Audio:
Fever = Red or Yellow temp range: 10 short beeps
Operating temperature:
15°C – 40°C ( 59°F – 104°F )
Automatic Switch-off:
Approx. 60 seconds after last measurement has been taken
Weight:
99.5g. (with battery), 77.1g. (w/o battery)
Service life:
5 years
Long term storage ranges
Storage/transport temperature:
–25°C to 60°C (–13°F to 140°F)
Humidity:
15–95% non condensing
Battery:
(2) AA Batteries - at least 1000 measurements
Pressure:
700-1060hPA (0.7-1.06 atm)
14
This infrared thermometer meets requirements established in ASTM Standard E
1965-98 for the thermometer system. Full responsibility for the conformance of the
product to the standard is assumed by Kaz Europe Sàrl, Place Chauderon 18,
CH-1003 Lausanne - Switzerland.
ASTM laboratory accuracy requirements for the thermometer only in the display range
of 36°C to 39°C (96.8°F to 102.2°F) for infrared thermometers is ± 0.2°C (± 0.4°F),
whereas for mercury-in-glass and electronic thermometers, the requirement per ASTM
Standards E 667-86 and E 1112-86 is ± 0.1°C (± 0.2°F).
This device conforms to the following standards:
IEC 60601-1:2006 Medical electrical equipment. General requirements for basic
safety and essential performance
ISO 80601-2-56 Particular requirements for basic safety and essential performance
of clinical thermometers for body temperature measurement
ASTM 1965E – ASTM Standard for Infrared Clinical Thermometers
EN 12470-5: 2003 «Clinical thermometers» – Part 3: Performance of compact
electrical thermometers (non-predictive and predictive) with maximum device.
IEC 60601-1-2: General requirements for basic safety and essential performance –
Collateral Standard: Electromagnetic compatibility –
Requirement and tests
NOTE: Do not use this device in the presence of electromagnetic or other
interference outside the normal range specified in IEC 60601-1-2.
EN 980: 2008 Symbols for use in labeling of medical devices. EN 1041: 2008
Information supplied by the manufacturer of medical devices. EN 60601-1-11: 2010
Medical electrical equipment -- Part 1-11: General requirements for basic safety and
essential performance -- Collateral standard: Requirements for medical electrical
equipment and medical electrical systems used in the home healthcare environment.
TYPE BF EQUIPMENT
Internally Powered ME Equipment
Continuous Operation
IP20, EN IEC 60601-1-11: 2010 Requirements for medical electrical equipment and
medical electrical systems used in the home healthcare environment.
Medical electrical equipment needs special precautions regarding EMC.
For detailed description of EMC requirements please contact consumer relations.
Portable and mobile RF communications equipment can affect medical electrical
equipment.
15