Record
Selects whether to save the text data or not.
Monitoring
Selects whether to display the text data on a monitor.
Sync with Text
Selects the channels to interlock with text information.
Seek Header
Data in a variety of types is transferred from external devices (Access Control, POS, ATM). If protocols
such as Star Finger 007 have already been registered and supported, this menu is not required. If not, this
menu is required as the parameter to identify the configuration of data in text information that is
continuously transferred. That is, all data has a starting and ending point. The Header means information
inserted to indicate the starting point. When Header information is defined in this menu, and the SVR-
1630 detects the relevant characters, the SVR-1630 identifies that the header is the starting point for one
piece of data. This menu allows you to set two headers, enabling detection of up to two headers,
because one device can transfer a variety of data to external devices.
Delimiter
Each device can require different Delimiter values. Please contact your local vendor or see the relevant
manual
Timeout (ms)
The number of lines defined below means the maximum number of text lines that one piece of data can
use. Although data is standardized, the data can be long or short. For example, ATM sets three lines on the
field for customer names. If one person registers only their first and last name, that person will use two
lines less than others when using ATM. The SVR-1630 can't automatically detect this difference. So the
SVR-1630 considers the last line as the final line after a certain period of time from the final input, and
decides whether to save the input data as complete data.
Lines
Defines the maximum lines for one piece of data.