·When installing the unit in an area that is enclosed on four sides
such as a verandah, be sure to leave move than 200mm behind
the unit as shown.
·When there is a lack of airflow or there is a possibility of becom-
ing short cycle, install an outlet guide and make sure there is en-
ough space behind the rear side of the air inlet.
NOTE:
Make sure not to install several outdoor units sideways next
to each other.
Window
More than 100mm
More than
100mm
More than 100mm
Less than 1,200 mm of the
front surface side
4-2 INSTALLING THE UNIT
·Be sure to fix the unit`s legs with bolts when installing it.
·Be sure to install the unit firmly to ensure that it does not fall
by earthquake or gust.
4-3 MOUNTING ARRANGEMENT OF DRAIN SOCKET
Please perform the drain piping work only when draining from
one place.
CAUTION
Do not use drain socket and drain cap in the cold region.
Drain may freeze and it makes the fan stop.
More than
More than
350mm
200mm
4-4 OUTDOOR WIRE CONNECTION AND OUTDOOR
POWER SUPPLY CORD CONNECTION
·Be sure to lead in the power supply cord to the air conditioner
in accordance with the specification tables below and ``Techni-
cal Standards for Electrical Installation``.
· Be sure to use special circuits for room air conditioner.
·Connect to the power switch which has a gap of 3mm or more
then open to interrupt the source power phase.
·When the power switch is shut off, it must interrupt all phases.
Input capacity Main switch/Fuse:20A
Power supply cord
specification
Indoor and outdoor
connecting wire specification
CAUTION
Attach an earth leakage breaker according to your installation
location. If any breaker is not attached, it may cause a risk of
electric shock.
06
2
Cable 3-core 2.5mm , in conformity with
Design 245 IEC 57.
2
Cable 4-core 0.75mm , in conformity with
Design 245 IEC 57.