Page 1
Thank you very much for purchasing this Air Conditioner. Please read this use and installation instructions carefully before installing and using this appliance and keep this manual for future reference.
Page 2
Welcome to use our product! Thanks for trusting us. Please read this manual carefully before installation! Keep it properly for future use after installation! Features of This Air-Conditioner Mute Operation Save Installation Space The excellent fan design enable the airflow The indoor unit is only as thick as 190mm, to be quiet and smooth with minimum noise.
Contents Installation and Maintenance ----------------------------------------------------------------------- 1. Safety Notice ------------------------------------------------ 2. The Tools and Instrument for Installation ----------------------------------------------------- 3. The Installation of the Indoor Unit ----------------------------------------------------------------- 3.1 Accessories ------------------------------------------------------------ 3.2 The Initial Check ----------------------------------------------------------------- 3.3 Installation ------------------------------------------------------------------ 4. Refrigerant Pipe -------------------------------------------------------------- 4.1 The Pipe Material -- -----------------------------------------------------...
CAUTION Statements We recommend that this air-conditioner be installed properly by qualified installation technicians in accordance with the installation instructions provided with the unit. Before installation, check if the voltage of the power supply in your home or office is the same as the voltage shown on the nameplate.
Composition of the Air-conditioner Indoor unit Air inlet Air outlet The conditioned air is blown out of the air-conditioner through it. Power cord Refrigerant Pipes Drainage pipe The indoor and outdoor units are connected by copper pipes through which the refrigerant flows. Outdoor unit SET TEMP ROOM TEMP...
Remote controller operation manual Wire emote controller introuce: LCD screen ROOM TEMP Wireless remoter receiver ON/OFF button TEMP. setting button FAN speed/FLAP button MODE select button TIMER/SLEEP button Room temperature sensor 1 . Room temperature sensor: A temperature sensor inside the remote control switch is set to sense room temperature, and the temperature will be sent to indoor unit.
Page 8
remote controller operation manual 8 .LCD screen Display room temperature and setting temperature Running state sign area Which SET TEMP indicate the running state ROOM TEMP Fan speed display Flap direction display (For duct AUTO type unit, this function is invalid) ERROR TIMER ON TIMER OFF SET TIMER...
remote controller operation manual 2. 2 sleep function ROOM TEMP Press timer/sleep button once to active sleep function. And sleep ”will appear on LCD. sign“ Press timer/sleep button again to cancel sleep function, and sleep sign on LCD will disappear. Note: During fan mode, the sleep function is invalid.
remote controller operation manual 3.wire Remote controller installation Installation of the wire remote controller please refer to the following: The wire remote controller must be installed by qualified installation technicians in accordance with installation drawing instruction, the power should be shut off before installation. Air flow and away from heating where the wire remote controller is installed.
Remote controller 4.Wireless remote controller Remote controller The remote controller transmits signals to the system. ON/OFF BUTTON The appliance will be started when it is energized or will be stopped when it is in operation, if you press this button. MODE BUTTON Press this button to select the operation mode.
Page 13
Remote controller Remote controller How to Insert the Batteries Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: Use 2 LR03 AAA(1.5volt) batteries.
Page 14
Operation instructions Operation modes Selecting mode Each time MODE button is pressed, the operation mode is changed in sequence: COOLING FAN ONLY HEATING Heating mode is NOT available for cooling only air conditioner. FAN mode Each time the "FAN" button is pressed, the fan speed is MODE CLOCK TIMER ON TIMER OFF...
Operation instructions Airflow direction control Airflow direction control Horizontal vertical airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. The direction of airflow can be Operation mode Direction of airflow also adjusted to your own requirement by pressing the horizontal...
Operation instructions SMART mode Press the SMART button, the unit enters SMART mode(fuzzy logic operation) directly regardless of the unit is on or off. In this mode, temperature and fan speed are automatically set based on the actual room temperature. Operation mode and temperature are determined by indoor temperature Heat pump models Indoor temperature...
Operation instructions Timer mode It is convenient to set the timer on with TIMER ON buttons when you go out in the morning To achieve a comfortable room temperature at the time you get home. You can also set Timer off at night to enjoy a good sleep with TIMER OFF How to set TIMER ON TIMER ON button can be used to set the timer programming as wished in order to...
Operation instructions SLEEP mode SLEEP mode SLEEP mode can be set in COOLING, HEATING or DRYING operation mode, This function gives you a more comfortable environment for sleep. In SLEEP mode, MODE CLOCK TIMER ON TIMER OFF The appliance will stop operation automatically after operating for 8 hours. SWING SMART SLEEP...
Page 19
Remote controller Remote controller The remote controller transmits signals to the system. ON/OFF BUTTON The appliance will be started when it is energized or will be stopped when it is in operation, if you press this button. MODE BUTTON Press this button to select the operation mode. FAN BUTTON Used to select fan speed in sequence auto, high, medium or low.
Page 20
Remote controller Remote controller How to Insert the Batteries Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: Use 2 LR03 AAA(1.5volt) batteries.
Operation instructions Operation modes Selecting mode Each time MODE button is pressed, the operation mode is changed in sequence: COOLING FAN ONLY HEATING Heating mode is NOT available for cooling only air conditioner. FAN mode Each time the "FAN" button is pressed, the fan speed is changed in sequence: ON/OFF Auto...
Operation instructions Airflow direction control Airflow direction control Vertical and horizontal airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. The direction of airflow can be ON/OFF Operation mode Direction of airflow also adjusted to your own requirement by pressing the horizontal...
Operation instructions SMART mode Press the SMART button, the unit enters SMART mode(fuzzy logic operation) directly regardless of the unit is on or off. In this mode, temperature and fan speed are automatically set based on the actual room temperature. Operation mode and temperature are determined by indoor temperature Heat pump models Indoor temperature...
Operation instructions Timer mode It is convenient to set the timer on with TIMER ON buttons when you go out in the morning To achieve a comfortable room temperature at the time you get home. You can also set timer off at night to enjoy a good sleep with TIMER OFF. How to set TIMER ON TIMER ON button can be used to set the timer programming as wished in order to switch on the appliance at your desired time.
Operation instructions SLEEP mode SLEEP mode SLEEP mode can be set in COOLING, HEATING,DRYING operation mode. This function gives you a more comfortable environment for sleep. In SLEEP mode, ON/OFF The appliance will stop operation automatically after operating for 8 hours. Note: Heating is NOT available for cooling only air conditioner.
remote controller operation manual -E4-07 Remote controller The remote controller transmits signals to the system. ON/OFF BUTTON The appliance will be started when it is energized or will be stopped when it is in operation, if you press this button. MODE BUTTON Press this button to select the operation mode.
Page 27
remote controller operation manual How to Insert the Batteries Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: Use 2 LR03 AAA(1.5volt) batteries.
Page 28
remote controller operation manual Operation mode Selecting mode Each time MODE button is pressed, the operation mode is changed in sequence: COOLING FAN ONLY HEATING Heating mode is NOT available for cooling only air conditioner. FAN mode Each time the "FAN" button is pressed, the fan speed is changed in sequence: Auto High...
remote controller operation manual Airflow direction control (invalid for this model) Airflow direction control Vertical airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. The direction of airflow can be Operation mode Direction of airflow also adjusted to your own MODE...
remote controller operation manual SMART mode (invalid for this model) Press the SMART button, the unit enters SMART mode(fuzzy logic operation) directly regardless of the unit is on or off. In this mode, temperature and fan speed are automatically set based on the actual room temperature.
remote controller operation manual Timer mode It is convenient to set the timer on with TIMER ON button when you go out in the morning To achieve a comfortable room temperature at the time you get home. You can also set timer off with TIMER OFF button at night to enjoy a good sleep.
remote controller operation manual SLEEP mode SLEEP mode SLEEP mode can be set in COOLING, HEATING,DRYING or SMART operation mode. This function gives you a more comfortable environment for sleep. In SLEEP mode, The appliance will stop operation automatically after operating for 8 hours. MODE Note: Heating is NOT available for cooling only air conditioner.
Operation manual 5. Special remarks · 3 minutes protect after compressor stop For protect compressor, there are at lest 3 minutes stopping after compressor stop. · 5 minutes protect Compressor must run 5 minutes at least once running. In the 5 minutes, compressor will not stop even the room temperature reach the setting point unless you use remoter to turn off the unit(all indoor unit be turned off by user).
Installation and Maintenance 1. Safety Notice WARNING · Installation should be left to the dealer or another professional person. (Improper installation may cause water leakage, electrical shock, or fire.) · Install the unit according to the instruction given in this manual. (Incomplete installation may cause water leakage, electrical shock, or fire.) ·Be sure to use the supplied or specified installation parts.
Installation and Maintenance 2. The Tools and Instruments for Installation Number Tool Number Tool Standard screwdriver Knife or wire stripper Vacuum pump Gradienter Charge hose Hammer Pipe bender Churn drill Adjustable wrench Tube expander Tube cutter Inner hexagon spanner Cross head screw-driver Tape measure 3.
Installation and Maintenance 3.3 Installation Optimum air distribution is ensured. The air passage is not blocked. 3.3.1 Suspension bolts Condensate can drain properly. (1) Consider the pipe direction, wiring and maintenance The ceiling is strong enough to bear the weight of carefully, and choose the proper direction and location the indoor unit.
Page 37
Installation and Maintenance Hanger bracket The capacity Suspension bolt 9k,12k,18k Rack 3.3.3 Install the indoor unit. Double nuts and washers The installation of the indoor unit is shown in Fig3.3.3 Suspension Bolts (4-M10 or W3/8) Fig 3.3.5 ( Field supplied ) 3.3.4 The horizon adjustment of the indoor unit (1) Make sure that the hanger bracket is fixed by the nut and the washer.
Installation and Maintenance The 18k indoor unit include the switch tie-in accessory only Static pressure Static pressure for 18K indoor, It may switch 9.52 gas connection tube into Canvas duct Canvas duct 12.7 connection tube,it is installed outdoor unit for Fig4.2.2.1. The valve for the amount of air Insulation material...
Installation and Maintenance 5. Drain pipe Drain pump hole · Install the drain pipe Refrigerant pipes · The two areas below should be insulated because condensation may form there causing water to leak. · Drain pipe passing indoors · Drain sockets. ·...
Installation and Maintenance 6. Electrical wiring 6. 1 General check (1) make sure that the field-selected electrical components(main power switches, circuit breakers, wire conduit connectors and wire terminals) have been properly selected according to the electrical data. Make sure that the components comply with national electrical code(NEC). (2) check to ensure that the power supply voltage is within ±10% of the rated voltage.
Installation and Maintenance WARNING ·If the fuses burn up, please call the service agency to instead it. Please do not instead by yourself, or else may result in accident, for example shock. 6.3 change of Static pressure The standard static pressure outside the indoor unit is 10 Pa. If you need high static pressure 30Pa, then you may change white fan motor terminal into red , refer to the following Fig6.4 .
PACKING LIST NAME AMOUNT INDOOR UNIT MANUAL WIRE REMOTE CONTROLLER INSTALLATION ACCESSORIES1 INSTALLATION ACCESSORIES2 INSTALLATION ACCESSORIES3 7* . SWITCH TIE-IN ACCESSORIES *NOTE:only 18K indoor unit contain the switch tie-in accessory. Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU.