4-1 FREE SPACE REQUIRED AROUND OUTDOOR UNIT(Unit:mm)
Obstacles
When there is an obstacle around the outdoor unit, it does not matter if the position of the obstacle as shown in the figures below.
(1).Obstacle over the top side.
100 or more
500 or more
(5).Service space
Keep the service space as shown
in the figure below for maintenance
Service space
100 or more
100 or more
500 or more
350 or more
(2).Obstacle in three direction(bu top
side is open) .
200 or more
100 or more
350 or more
500 or more
(3).Obstacle on front(blowing)
side only. In this case, the
rear, both side and top sh-
ould be open.
500 or more
05
(4).Obstacle on front and rear side
only. The unit can be used by
attaching an optional outdoor
blowing guide(but both sides and
top are open).
100 or more
500 or more
Blowing guide