5058-030
Fuser assembly removal
This removal procedure applies to the100V, 110V, and 220V fuser assemblies.
Open the printer left duplex door assembly.
1.
Remove the two thumbscrews (A).
2.
3.
Use the handles (B) to pull the fuser assembly out of the machine.
Fuser cooling fan removal
Remove the rear upper cover. See
1.
Disconnect the input option cable (A).
2.
Service Manual
4-78
"Rear upper cover removal" on page