7.5.5 Replacing milk regulator assembly

821
Unplug connector for milk regulator (821) from electronic mainboard (806).
Remove 3 cable clips (111) from holder (1) by pressing the retention latches
inwards.
Loosen 3 screws (TX 10) and remove milk regulator (821).
Assembly checkpoint
Use cable guides on holder for milk regulator (77) and cable clips (111) to secure
wires.

7.5.6 Reassembly and wiring instructions - Gran Maestria

Reassembly checkpoints
Check if light guide (115) is mounted before attaching upper part of housing (114).
Check if permanent magnet (142) for drip tray is inserted in base (141). Remove
mounting aid (additional magnet) if present.
Take care not to jam any wires between base and upper part (especially wiring of
electronic main board).
111
Maestria / Gran Maestria service manual
R E P A I R S
77
Do not lose cable
clips!