For wiring of elec-
tronic mainboard
refer to page 49.
66
R E P A I R S
7.4.14 Replacing support for cup holder
807
70
•
Loosen screw (TX 10) and remove relieve tank (820, Maestria only).
•
Loosen 2 screws (TX 10) and remove support (807) for cup holder together with
spring (70).
7.4.15 Reassembly and wiring instructions - Maestria
Reassembly checkpoints
•
Check if permanent magnet (161) for drip tray is inserted in base (160). Remove
mounting aid (additional magnet) if present.
•
Take care not to jam any wires between base and upper part (especially wiring of
electronic main board).
Wiring instructions and checks
A final wiring check must be conducted before mounting the side panels and the bottom
cover.
Refer to the following left and right side views for critical places and spots where wiring
problems can appear.
Maestria / Gran Maestria service manual
820