Remove flow meter hose from water tank connector (see "Replacing water tank
connector" on page 47).
1
Unlatch lower pump holder (14 / 196): Insert screwdriver blade into gap between
pump holder and holder (1). Then swivel screwdriver and move out pump assembly
with flow meter (22) partly.
Remove upper pump holder (15 / 197): Press in both wedges one after another with
a screwdriver and pull out upper pump holder from the machine.
Disconnect the cable from flow meter (22) and remove the pump assembly
completely.
22
14
(196)
Maestria / Gran Maestria service manual
R E P A I R S
Upper (15 / 197) and
lower (14 / 196) pump
holders have stop-
pers and latches.
15
(197)