Save A Service Call - Raypak B0507 Owner's Manual And Installation Instructions

Table of Contents

Advertisement

Check the items below before making a service call. You will be charged for attending to any condition or
fault that is not related to manufacture or failure of a part.
NOT ENOUGH HOT WATER (OR NO HOT WATER)
Is the electricity switched on?
Inspect the isolation switch adjacent to the water heater and ensure the
isolation switch is turned on.
Is there a time clock on the power supply?
Check the settings on the time clock to ensure they are suitable to enable
heating when required.
Is the ignition system 'locked out'?
Reset the water heater. Refer to
Is a code displayed on the electronic thermostat?
Check the LED display on the electronic thermostat (refer to the diagnostic
features for the relevant electronic thermostat installed as detailed on page 8).
Are you using more hot water than you think?
Are outlets (especially the showers) using more hot water than you think? Very often it is not realised the
amount of hot water used, particularly when showering. Carefully review the hot water usage. Have your
plumber fit a flow control valve to each shower outlet to reduce water usage.
Pressure relief valve running
Is the relief valve discharging too much water? (Refer to
Electronic thermostat temperature setting
Ensure the electronic thermostat temperature setting (set point) is appropriate. You may choose to have your
installer adjust the temperature setting upwards to gain additional hot water capacity.
Warning: Hotter water increases the risk of scald injury.
Water heater size
Do you have the correct size water heater for your requirements? The sizing guide in the Raypak sales
literature and on the Rheem website
WATER HEATER NOT OPERATING
If the system water temperature is abnormally low, the ignition system may have „locked out‟. A lockout condition is
indicated by the reset button being illuminated. If this occurs, the ignition system can be reset as follows:
Wait five (5) minutes for unburnt gas to escape which may be present from a previous failed ignition attempt.
Press and hold the reset button for approximately 1 second (the reset button light should extinguish).
If the water heater still fails to operate, call your nearest Rheem Service Department or Accredited Service Agent to
arrange for an inspection.
DIAGNOSTIC FEATURES OF IC902 ELECTRONIC THERMOSTAT
On/Off models incorporate an IC902 electronic thermostat. In the event of a temperature sensor fault occurring, a
code will be shown on the thermostat display to diagnose the fault.
DIAGNOSTIC FEATURES OF RWF55 ELECTRONIC THERMOSTAT
Modulating models incorporate an RWF55 electronic thermostat. In the event of a temperature sensor fault
occurring, a code will be shown on the thermostat display to diagnose the fault.
Upper window (red)
9999 (flashing)
-1999 (flashing)
9999 (flashing)
-1999 (flashing)

SAVE A SERVICE CALL

"Water Heater Not Operating"
(www.rheem.com.au)
Code
E1
Lower window (green)
Current set point
Current set point
tA
tA
on page 8.
"Pressure Relief Valve Running"
suggests average sizes that may be needed.
Water temperature sensor open or short circuited
Water temperature sensor open circuited
Water temperature sensor short circuited
Outdoor compensation temp sensor open circuited
Outdoor compensation temp sensor short circuited
8
on page 9).
Fault
Fault