Power Up And Bind A Radiator Controller; Radiator Controller (Hr80) - Honeywell evohome Installation Manual

Hide thumbs Also See for evohome:
Table of Contents

Advertisement

22

Radiator Controller (HR80)

evohome
Controller
If you are NOT
following GUIDED
CONFIGURATION
follow these steps
on your evohome
Controller display first:
1. On the evohome
Controller press and
hold "Settings"
for
3 seconds
2. Press the green tick
3. Press ADD ZONE
4. Press the zone you
want to add the
controller to
5. Rename the zone if
required and/or press
the green tick
6. Press RADIATOR
VALVE
Step 3: Power up and bind devices

Power up and bind a Radiator Controller

(HR80)
If you want to control the zone temperature with your evohome
Controller (the evohome Controller needs to be located in that
zone) press YES, otherwise press NO and bind the sensor.
On the HR80, you need to bind the
sensor and actuator separately
Power up the Radiator Controller (see HR80 instructions)
1
To bind the sensor
On the evohome Controller press
2
the green bind button
Turn release clips on each side of the Radiator
3
Controller to remove the bottom plate
On the underside of the Radiator Controller
4
press the recessed bind button
The Radiator Controller screen should briefly show
5
a flashing RF icon
The evohome Controller will also show if binding
was successful (if not go back and re-bind)
4
SIDE VIEW
then SYNC when successful.
BOTTOM VIEW