Fujitsu AUU7RLF Design & Technical Manual page 138

2/3/4 rooms type
Hide thumbs Also See for AUU7RLF:
Table of Contents

Advertisement

COMPLETION OF FUNCTION SETTING MODE
(8) Press the "RESET" button.
SETTING UP EACH INDOOR UNIT
RESET THE POWER AFTER SETTING UP FUNCTION OF ALL
INDOOR UNITS
Important
If the reset is not performed, function can not be read in normally.
After all the functions have been set, the circuit breaker needs to be switched off for at least
2 minutes.
After the 2 minutes has passed, power can be restored.
The set fuction is stored in the PCB and will remain in memory even when the power is
turned off.
However setting function is effective after power reset.
Record the function set in the indoor unit on a label, etc., and affix the label to the unit so it
can be used for after-sales service operations.
Once the "RESET" button is pressed on the remote controller, the OPERATION MODE will be
Ü
set in the "AUTO MODE".
Please adjust the OPERATION MODE to either "COOLING" or "HEATING" before trying to
operate the air conditioner.
Note : If CUSTOM CODE is set to anything other than "A" ,the remote control must be set
Ü
accordingly to the INDOOR UNIT setting.
RESET
Repeat steps (1) through to (8). Steps (1) through to (2)
and (8) only need to carried out if the custom code is
different to the factory setting of "A".
- (01 - 134) -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents