Value Range
Default Value
USE_DEL_REG_CLOSE_n
Parameter Name Example
Value Format
Description
Value Range
Default Value
PORT_PUNCH_INTVL_n
Parameter Name Example
Value Format
Description
Value Range
Default Value
Web User Interface Reference
SIP_ADD_RPORT_n
Parameter Name Example
Value Format
Description
Document Version 2013-03
•
Y (Enable cancelation before registration)
•
N (Disable cancelation before registration)
N
USE_DEL_REG_CLOSE_1, USE_DEL_REG_CLOSE_2, ...,
USE_DEL_REG_CLOSE_6
Boolean
Specifies whether to enable the cancelation of registration before the
SIP function shuts down when, for example, the configuration has
changed.
•
Y (Enable registration cancelation before shutting down)
•
N (Disable registration cancelation before shutting down)
Note
•
If set to "Y", registration cancelation is enabled.
•
If set to "N", registration cancelation is disabled even when the
SIP stack is shutting down.
N
PORT_PUNCH_INTVL_1, PORT_PUNCH_INTVL_2, ...,
PORT_PUNCH_INTVL_6
Integer
Specifies the interval, in seconds, between transmissions of the Keep
Alive packet to the unit in order to maintain the NAT binding information.
Note
•
This setting is available only when "SIP_TRANSPORT_n" is set
to "0" for UDP.
0, 10–300 (0: Disable)
0
Keep Alive Interval (Page 114)
SIP_ADD_RPORT_1, SIP_ADD_RPORT_2, ..., SIP_ADD_RPORT_6
Boolean
Selects whether to add the 'rport' parameter to the top Via header field
value of requests generated. For details, refer to RFC 3581.
5.7.2 SIP Settings
Administrator Guide
259