IVT 12KHR-N Service Manual page 26

Split type air to air heat pump
Table of Contents

Advertisement

12KHR-N
2. Outdoor unit
Item
Mode
Compressor
Cooling
chamber ther-
Dehumidifying
mistor (TH1)
Heating
Heat exchanger
Cooling
thermistor (TH2)
Dehumidifying
Heating
Outside air tem-
Auto
perature ther-
mistor (TH3)
Cooling
Dehumidifying
Heating
Suction pipe ther-
Cooling
mistor (TH4)
Dehumidifying
Heating
2-way valve ther-
Cooling
mistor (TH5)
Dehumidifying
Heating
Control opera-
When resis-
tion
tance is low
(temperature
judged higher
than actual)
Expansion valve
Compressor
control and com-
operates, but
pressor protection
room does not
become cool or
warm (expansion
valve is open).
Outdoor unit heat
Compressor
exchanger over-
operates at low
heat prevention
speed or stops.
Expansion valve
Defrosting opera-
control
tion is not acti-
Defrosting
vated as needed,
and frost accumu-
lates on outdoor
unit (expansion
valve is closed).
Operation mode
Cooling mode is
judgment
activated even if
room tempera-
ture is low.
Operation not
Normal operation.
affected
Rating control
Defrosting opera-
Defrosting
tion is activated
unnecessarily.
Expansion valve
Compressor
control
operates, but
room does not
become cool
(expansion valve
is open).
Expansion valve
Compressor
control
operates, but
room does not
become warm
(expansion valve
is open).
Expansion valve
Frost accumu-
control
lates on indoor
unit evaporator
and room does
not become cool
(expansion valve
is closed).
Operation not
Normal operation.
affected
Short-circuit
Compressor high
temperature error
indication.
Outdoor unit ther-
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
mistor short-cir-
cuit error
indication.
3 – 4
When resis-
Open-circuit
tance is high
(temperature
judged lower
than actual)
Layer short-cir-
Outdoor unit ther-
cuit or open-cir-
mistor open-cir-
cuit may result in
cuit error
compressor in
indication.
normal operation.
Normal operation.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Defrosting opera-
Outdoor unit ther-
tion is activated
mistor open-cir-
unnecessarily,
cuit error
and room does
indication.
not become warm
(expansion valve
is open).
Heating mode is
Outdoor unit ther-
activated even if
mistor open-cir-
room tempera-
cuit error
ture is high.
indication.
Normal operation.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Defrosting opera-
Outdoor unit ther-
tion is not acti-
mistor open-cir-
vated, and frost
cuit error
accumulates on
indication.
outdoor unit.
Frost accumu-
Outdoor unit ther-
lates on evapora-
mistor open-cir-
tor inlet section,
cuit error
and room does
indication.
not become cool
(expansion valve
is closed).
Frost accumu-
Outdoor unit ther-
lates on expan-
mistor open-cir-
sion valve outlet
cuit error
section, and room
indication.
does not become
warm (expansion
valve is closed).
Compressor
Outdoor unit ther-
operates, but
mistor open-cir-
room does not
cuit error
become cool
indication.
(expansion valve
is open).
Normal operation.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.