IVT 12KHR-N Service Manual page 24

Split type air to air heat pump
Table of Contents

Advertisement

12KHR-N
Function
9
AC overcurrent
Operating frequency lowers if out-
error
door AC current exceeds peak
control current value. outdoor
stops if compressor AC current
exceeds peak control current
value at minimum frequency.
10 AC overcurrent
Indoor and outdoor units stop if
error in compressor
outdoor AC current exceeds
OFF status
about 3 A while compressor is in
non-operation status.
11
AC maximum cur-
Compressor stops if coutdoor AC
rent error
current exceeds 17 A.
12 AC current defi-
Compressor stops if operating
ciency error
frequency is 50 Hz or higher and
outdoor AC current is about 2.0 A
or lower.
13 Thermistor installa-
Compressor stops if high and low
tion error or 4-way
values of temperatures detected
valve error
by outdoor unit heat exchanger
thermistor (TH2) and 2-way valve
thermistor (TH5) do not match
operating cycle.
14 Compressor high
Compressor stops if compressor
temperature error
chamber thermistor (TH1)
exceeds about 114 C, or if there
is short-circuit in TH1.
15 Outdoor unit heat
Compressor stops if there is
exchanger ther-
short-circuit in outdoor unit heat
mistor short-circuit
exchanger thermistor (TH2).
error
16 Outdoor unit outside
Compressor stops if there is
air temperature
short-circuit in outdoor unit out-
thermistor short-cir-
side air temperature thermistor
cuit error
(TH3).
17 Outdoor unit suction
Compressor stops if there is
thermistor short-cir-
short-circuit in outdoor unit suc-
cuit error
tion thermistor (TH4).
18 Outdoor unit 2-way
Compressor stops if there is
valve thermistor
short-circuit in outdoor unit 2-way
short-circuit error
valve thermistor (TH5).
19 Outdoor unit heat
Compressor stops if there is
exchanger ther-
open-circuit in outdoor unit heat
mistor open-circuit
exchanger thermistor (TH2).
error
20 Outdoor unit outside
Compressor stops if there is
air temperature
open-circuit in outdoor unit out-
thermistor open-cir-
side air temperature thermistor
cuit error
(TH3).
21 Outdoor unit suction
Compressor stops if there is
thermistor open-cir-
open-circuit in outdoor unit suc-
cuit error
tion thermistor (TH4).
22 Outdoor unit 2-way
Compressor stops if there is
valve thermistor
open-circuit in outdoor unit 2-way
open-circuit error
valve thermistor (TH5).
23 Outdoor unit dis-
Compressor stops if there is
charge thermistor
open-circuit in outdoor unit dis-
open-circuit error
charge thermistor (TH1).
24 Serial signal error
Compressor stops if outdoor unit
cannot receive serial signal from
indoor unit for 30 seconds.
25 Compressor star-
Compressor stops if compressor
tup error
fails to start up.
Description
Detection period
When compressor is
in operation
When compressor is
in non-operation
When compressor is
in operation
When compressor is
in operation
3 minutes after com-
pressor startup
When in operation
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
When in operation
At compressor star-
tup
Operation
Reset condition
Operation OFF or ON Yes $1
Replacement of
defective parts such
as IPM
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Operation OFF or ON Yes $1
Reset after reception
of serial signal
Operation OFF or ON Yes $3
3 – 2
Self-diagnosis
result display
Indoor
Indoor
Outdoor
unit
unit
unit
error
display
Yes
Yes
Yes $2
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
None
None
None
Yes
Yes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents